• Users Online: 111
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 23  |  Issue : 2  |  Page : 191-195

Gaseous pollutants in Indian EKM and SSK class submarines


1 FMO (West), Mumbai, Maharashtra, India
2 Classified Spl (Medicine) and Gastroenterology, Department of Gastroenterology, INHS Asvini, Mumbai, Maharashtra, India
3 School of Naval Medicine (SNM), INHS Asvini, Mumbai, Maharashtra, India

Correspondence Address:
Surg Capt (Dr) Vivek Verma
INM, INHS Asvini, Colaba, Mumbai - 400 005, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmms.jmms_61_19

Rights and Permissions

Introduction: Once a submarine dives, the captive atmosphere inside keeps changing due to release of various pollutant gases. The gases are produced by machinery, cooking, human, paints, batteries, cooking etc. The study was envisaged to measure these gaseous pollutants on surface and in prolonged dive onboard EKM and SSK class submarines. Methods and Material: Detector tubes and pumps were used to measure the concentration of twenty gaseous pollutants in harbour on surface & during sailing in dived condition. In harbour, readings were taken early morning and before secure in the evening. During sailing readings were taken on surface, just after diving and thereafter every four hrs. The readings were recorded in excel sheet and correlated with activities on board at time of taking reading. Results: Only Ammonia and Hydrogen Sulphide were detected at the beginning of the day in harbour, however by the end of the day all other gases were detected except Mercury, Oil mist, Nitrogen Dioxide, Ozone & Arsine. At Sea none of the gases were detected at the beginning of sailing. At 12h post dive all gases were detected except Mercury, Oil mist, Nitrogen Dioxide, Ozone, Halogenated Hydrocarbons & Arsine. Recommendations and Conclusion: The gas concentration values obtained by using detector tubes and pumps were found to be within recommended Permitted Exposure Levels (PEL) for human for continuous exposure. No gas was found to be above the recommended PEL. There was no significant difference in the gas concentration levels in the EKM & SSK Class submarines. Pump and detector tube is a convenient, reasonably accurate and efficient method to measure gaseous pollutants on board Submarines.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed758    
    Printed6    
    Emailed0    
    PDF Downloaded16    
    Comments [Add]    

Recommend this journal